Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
1.
J Clin Lab Anal ; 35(12): e24087, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34724262

RESUMO

BACKGROUND: The measurement method for experimental resolution and related data to evaluate analytical performance is poorly explored in clinical research. We established a method to measure the experimental resolution of clinical tests, including biochemical tests, automatic hematology analyzer methods, immunoassays, chemical experiments, and qPCR, to evaluate their analytical performance. METHODS: Serially diluted samples in equal proportions were measured, and correlation analysis was performed between the relative concentration and the measured value. Results were accepted for p ≤ 0.01 of the correlation coefficient. The minimum concentration gradient (eg, 10%) was defined as the experimental resolution. For this method, the smaller the value, the higher the experimental resolution and the better the analytical performance. RESULTS: The experimental resolution of the most common biochemical indices reached 10%, with some even reaching 1%. The results of most counting experiments showed experimental resolution up to 10%, whereas the experimental resolution of the classical chemical assays reached 1%. Unexpectedly, the experimental resolution of more sensitive assays, such as immunoassays was only 25% when using the manual method and 10% for qPCR. CONCLUSION: This study established a method for measuring the experimental resolution of laboratory assays and provides a new index for evaluating the reliability of methods in clinical laboratories.


Assuntos
Análise Química do Sangue/métodos , Técnicas Imunológicas/métodos , Laboratórios Clínicos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Contagem de Células Sanguíneas , Análise Química do Sangue/normas , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Técnicas Imunológicas/normas , Laboratórios Clínicos/normas , Reação em Cadeia da Polimerase em Tempo Real/normas , Reprodutibilidade dos Testes , Espectrofotometria Atômica
2.
Int J Infect Dis ; 104: 85-91, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33359066

RESUMO

OBJECTIVES: The aim of this study was to evaluate the development and status quo of the quality of high throughput in vitro diagnostic testing for tetanus and diphtheria antitoxin antibody (ATX) concentrations based on external quality assessment (EQA) data. METHODS: We analyzed manufacturer-specific data of 22 EQA surveys-each for the detection of tetanus and diphtheria ATX-to check the diagnostic strength of the corresponding in vitro diagnostic systems. RESULTS: While the results were mostly well aligned, individual surveys showed widely dispersed ATX concentrations. The medians of manufacturer collectives deviated from the overall median by up to 8.9-fold in the case of diphtheria ATX and by up to 3.5-fold in the case of tetanus ATX. Such a distribution in the results is particularly critical in the cut-off range for immunity and may lead to an incorrect assessment of vaccination status. CONCLUSION: These results were surprising as there are International Standards for both ATX; however, the results may be linked to the high ATX concentration of the reference material, which deviates considerably from clinically significant concentrations. To increase the accuracy and diagnostic strength of both assays, we recommend a recalibration of the test systems and verification of their traceability to the International Standards.


Assuntos
Antitoxina Diftérica/sangue , Antitoxina Tetânica/sangue , Difteria/imunologia , Humanos , Técnicas Imunológicas/normas , Ensaio de Proficiência Laboratorial , Tétano/imunologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-33276389

RESUMO

OBJECTIVE: Knowledge of cross-reactions in food-sensitive dogs will influence the choice of elimination diets and the long-term management of those patients. The objective of this study was to evaluate food allergen-specific IgE tests of suspected allergic dogs for concurrent positive reactions as possible evidence for cross reactions between allergens. MATERIAL AND METHODS: Results of serum IgE tests from 760 suspected allergic dogs submitted to 2 laboratories were evaluated statistically. After the tested allergens were grouped by their phylogenetic relationship, odds ratios as well as a sensitivity analysis of the odds ratios were performed to evaluate if concurrent positive IgE results to 2 allergens occurred more often than expected. RESULTS: Within related allergen pairs 27% (laboratory 1) and 72% (laboratory 2) of the pairs could be considered as associated. For the unrelated allergen pairs only 6.8% and 10.6% of the analyzed pairs were considered associated respectively. Strong correlations were shown in the group of ruminant allergens, especially beef and lamb, and grain allergens. High rates of concurrent reactions were also detected in the poultry group, especially between chicken and duck, as well as between pork and ruminant allergens, and soy and grain allergens. CONCLUSION: As our results showed not only correlations within related but also between non-related allergens, the possible relevance of carbohydrate moieties as well as panallergens for canine hypersensitivities warrants further study. Further investigations are necessary to distinguish co-sensitization from cross-reactions and determine the clinical relevance of food-specific IgE reactivity. CLINICAL RELEVANCE: Due to possible cross reactivity related allergens, especially beef and lamb as well as grain allergens, should not be used for an elimination diet to avoid false results.


Assuntos
Alérgenos , Doenças do Cão , Hipersensibilidade Alimentar , Imunoglobulina E/sangue , Técnicas Imunológicas , Alérgenos/classificação , Alérgenos/imunologia , Animais , Doenças do Cão/diagnóstico , Doenças do Cão/etiologia , Doenças do Cão/imunologia , Cães , Grão Comestível/efeitos adversos , Hipersensibilidade Alimentar/diagnóstico , Hipersensibilidade Alimentar/etiologia , Hipersensibilidade Alimentar/imunologia , Hipersensibilidade Alimentar/veterinária , Técnicas Imunológicas/métodos , Técnicas Imunológicas/normas , Técnicas Imunológicas/veterinária , Carne/efeitos adversos , Alimentos de Soja/efeitos adversos
4.
Ann Biol Clin (Paris) ; 78(6): 671-685, 2020 Dec 01.
Artigo em Francês | MEDLINE | ID: mdl-33237028

RESUMO

The ISO 15189 accreditation of biological analysis needs the validation of the analytical methods allowing the evaluation of their performance including all the factors that could influence the quality of their results. The field of autoimmunity includes many analyses and methods such as the indirect immunofluorescence technique (IIF) and the performance of this technique largely depends on the competency of staff members. For each staff member, the required levels of competency have to be precisely defined and evaluated after a period of formation before the final habilitation for the IIF technique. The French group of the international group called EASI (European autoimmunity standardisation initiative) proposes two habilitation forms to be filled with criteria, evidence and maintenance of target skills for the IIF preparation of slides and reading. These forms could be used as a model for the IIF formation and habilitation and have to be adapted to the routine practice of the laboratories.


Assuntos
Doenças Autoimunes/diagnóstico , Educação Continuada/normas , Técnicas Imunológicas/normas , Laboratórios/normas , Competência Profissional/normas , Acreditação , Doenças Autoimunes/imunologia , Autoimunidade/fisiologia , Testes Diagnósticos de Rotina/normas , Educação Continuada/métodos , Educação Continuada/organização & administração , Reeducação Profissional/métodos , Reeducação Profissional/organização & administração , Reeducação Profissional/normas , Técnica Indireta de Fluorescência para Anticorpo/métodos , Técnica Indireta de Fluorescência para Anticorpo/normas , França , Humanos , Padrões de Referência , Sociedades Científicas/organização & administração , Sociedades Científicas/normas , Estudos de Validação como Assunto
5.
J Clin Virol ; 115: 37-42, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30959325

RESUMO

BACKGROUND/OBJECTIVES: Determination of Cytomegalovirus (CMV) status in solid organ transplant (SOT) candidates is essential to stratify risk of post-transplant CMV disease. Passive transfusion-acquired antibodies can make serologic determination of CMV status unreliable. We evaluated 3 assays, not affected by passive antibodies (PA), in assignment of CMV status: quantification of CMV-specific CD4 + T-cells (CMV-TC) and exhausted CD27-CD28- CD4 + T-cells, and detection of CMV DNA with Nucleic Acid Amplification Testing (NAAT). STUDY DESIGN: We enrolled 50 adults awaiting SOT and 50 immunocompetent age-matched controls, and collected a throat swab, urine, saliva and blood sample on each. Using flow cytometry CD4 + T-cells were phenotypically analyzed for expression of CD27 and CD28 and CMV-specific CD4 + T-cells were identified by CD69 expression and intracellular IFN-γ quantification after stimulation with CMV-antigen lysate. CMV NAAT was performed on all specimens using real-time PCR. CMV serology (CMV IgG) was determined by enzyme immunoassay. Subjects were considered to have potential PA if they received blood products within 2 months of collection. RESULTS: The CMV-TC assay discriminated between CMV-seropositive and seronegative SOT candidates without PA well (sensitivity 79%, specificity 93%) while the CD27-CD28-CD4 + T-cell assay had good sensitivity (86%) but specificity of 74%. Detection of CMV DNA was uncommon in CMV-seropositive SOT candidates (2/21). CONCLUSIONS: Given its high specificity, the CMV-TC assay is valuable in confirming true-positive CMV status in seropositive SOT candidates with PA, while use of CD27-CD28-CD4 + T-cell analysis is limited by moderate specificity. Detection of CMV DNA is of limited value in assignment of CMV status in adults.


Assuntos
Antígenos CD28/imunologia , Linfócitos T CD4-Positivos/imunologia , Infecções por Citomegalovirus/diagnóstico , Técnicas Imunológicas/normas , Transplante de Órgãos , Membro 7 da Superfamília de Receptores de Fatores de Necrose Tumoral/imunologia , Adulto , Infecções por Citomegalovirus/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
7.
Front Immunol ; 10: 3151, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32117208

RESUMO

Antidrug antibody (ADA) responses impact drug safety, potency, and efficacy. It is generally assumed that ADA responses are associated with human leukocyte antigen (HLA) class II-restricted CD4+ T-cell reactivity. Although this review does not address ADA responses per se, the analysis presented here is relevant to the topic, because measuring or predicting CD4+ T-cell reactivity is a common strategy to address ADA and immunogenicity concerns. Because human CD4+ T-cell reactivity relies on the recognition of peptides bound to HLA class II, prediction, or measurement of the capacity of different peptides to bind or be natural ligands of HLA class II is used as a predictor of CD4+ T-cell reactivity and ADA development. Thus, three different interconnected variables are commonly utilized in predicting T-cell reactivity: major histocompatibility complex (MHC) binding, capacity to be generated as natural HLA ligands, and T-cell immunogenicity. To provide the scientific community with guidance in the relative merit of different approaches, it is necessary to clearly define what outcomes are being considered. Thus, the accuracy of HLA binding predictions varies as a function of what the outcome predicted is, whether it is binding itself, natural processing, or T-cell immunogenicity. Furthermore, it is necessary that the accuracy of prediction is based on rigorous benchmarking, grounded by fair, objective, transparent, and experimental criteria. In this review, we provide our perspective on how different variables and methodologies predict each of the various outcomes and point out knowledge gaps and areas to be addressed by further experimental work.


Assuntos
Linfócitos T CD4-Positivos/imunologia , Antígenos de Histocompatibilidade Classe II/imunologia , Técnicas Imunológicas/normas , Animais , Benchmarking , Epitopos de Linfócito T/imunologia , Humanos , Ligantes , Ligação Proteica/imunologia
8.
Transfusion ; 58 Suppl 3: 3106-3113, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30536434

RESUMO

Streptococcus pneumoniae (S. pneumoniae) strains colonize the nasopharynx and can cause mucosal infections in the upper airway and middle ear, pneumonias, and invasive infections like bacteremia, sepsis, and meningitis. Over 90 serotypes, defined by the structure of their capsular polysaccharides, are known. Twenty-three of these serotypes cause most infections and several of these serotypes can develop antibiotic resistance. Susceptibility factors that increase the susceptibility to S. pneumoniae mucosal and invasive infections include all forms of primary and secondary antibody deficiencies. Many patients affected by one of these deficiencies benefit from the regular administration of human gamma globulin (IgG) preparations. Donors of plasma units used to prepare human IgG have varying concentrations of IgG antibodies against relevant S. pneumoniae serotypes. These antibodies are developed in response to colonization and common subclinical infections and by routine vaccination with S. pneumoniae polysaccharide vaccines. The presence of an adequate concentration of these protective antibodies against all prevalent serotypes needs to be determined to assure the effectiveness of human IgG. All presently available methods to assess IgG antibodies against S. pneumoniae capsular polysaccharides have advantages and pitfalls that are analyzed in this review. In vitro testing does not provide a complete or necessarily accurate measurement of the effectiveness of antibodies in vivo. For regulatory purposes, caution needs to be used in the interpretation of currently available assays that measure pneumococcal antibody levels. Monitoring S. pneumoniae infections in patients treated with IgG and tracing information about IgG lots used to treat these patients should be encouraged.


Assuntos
Anticorpos Antibacterianos/metabolismo , Formação de Anticorpos/fisiologia , Imunoglobulina G/análise , Técnicas Imunológicas/normas , Infecções Pneumocócicas/imunologia , Infecções Pneumocócicas/prevenção & controle , Streptococcus pneumoniae/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Imunoglobulina G/administração & dosagem , Técnicas Imunológicas/métodos , Guias de Prática Clínica como Assunto , Potência de Vacina
16.
Appl Environ Microbiol ; 82(6): 1966-1975, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26773088

RESUMO

Ecological understanding of disease risk, emergence, and dynamics and of the efficacy of control strategies relies heavily on efficient tools for microorganism identification and characterization. Misdetection, such as the misclassification of infected hosts as healthy, can strongly bias estimates of disease prevalence and lead to inaccurate conclusions. In natural plant ecosystems, interest in assessing microbial dynamics is increasing exponentially, but guidelines for detection of microorganisms in wild plants remain limited, particularly so for plant viruses. To address this gap, we explored issues and solutions associated with virus detection by serological and molecular methods in noncrop plant species as applied to the globally important Barley yellow dwarf virus PAV (Luteoviridae), which infects wild native plants as well as crops. With enzyme-linked immunosorbent assays (ELISA), we demonstrate how virus detection in a perennial wild plant species may be much greater in stems than in leaves, although leaves are most commonly sampled, and may also vary among tillers within an individual, thereby highlighting the importance of designing effective sampling strategies. With reverse transcription-PCR (RT-PCR), we demonstrate how inhibitors in tissues of perennial wild hosts can suppress virus detection but can be overcome with methods and products that improve isolation and amplification of nucleic acids. These examples demonstrate the paramount importance of testing and validating survey designs and virus detection methods for noncrop plant communities to ensure accurate ecological surveys and reliable assumptions about virus dynamics in wild hosts.


Assuntos
Doenças das Plantas/virologia , Vírus de Plantas/isolamento & purificação , Plantas/virologia , Virologia/métodos , Técnicas Imunológicas/métodos , Técnicas Imunológicas/normas , Biologia Molecular/métodos , Biologia Molecular/normas , Testes Sorológicos/métodos , Virologia/normas
17.
J. investig. allergol. clin. immunol ; 26(1): 31-39, 2016. tab, ilus, graf
Artigo em Inglês | IBECS | ID: ibc-150187

RESUMO

Background: Component-based diagnosis on multiplex platforms is widely used in food allergy but its clinical performance has not been evaluated in nut allergy. Objective: To assess the diagnostic performance of a commercial protein microarray in the determination of specific IgE (sIgE) in peanut, hazelnut, and walnut allergy. Methods: sIgE was measured in 36 peanut-allergic, 36 hazelnut-allergic, and 44 walnut-allergic patients by ISAC 112, and subsequently, sIgE against available components was determined by ImmunoCAP in patients with negative ISAC results. ImmunoCAP was also used to measure sIgE to Ara h 9, Cor a 8, and Jug r 3 in a subgroup of lipid transfer protein (LTP)-sensitized nut-allergic patients (positive skin prick test to LTP-enriched extract). sIgE levels by ImmunoCAP were compared with ISAC ranges. Results: Most peanut-, hazelnut-, and walnut-allergic patients were sensitized to the corresponding nut LTP (Ara h 9, 66.7%; Cor a 8, 80.5%; Jug r 3, 84% respectively). However, ISAC did not detect sIgE in 33.3% of peanut-allergic patients, 13.9% of hazelnut-allergic patients, or 13.6% of walnut-allergic patients. sIgE determination by ImmunoCAP detected sensitization to Ara h 9, Cor a 8, and Jug r 3 in, respectively, 61.5% of peanut-allergic patients, 60% of hazelnut-allergic patients, and 88.3% of walnut-allergic patients with negative ISAC results. In the subgroup of peach LTP-sensitized patients, Ara h 9 sIgE was detected in more cases by ImmunoCAP than by ISAC (94.4% vs 72.2%, P<.05). Similar rates of Cor a 8 and Jug r 3 sensitization were detected by both techniques. Conclusions: The diagnostic performance of ISAC was adequate for hazelnut and walnut allergy but not for peanut allergy. sIgE sensitivity against Ara h 9 in ISAC needs to be improved (AU)


Introducción: La utilidad clínica del diagnóstico por componentes no ha sido evaluada en el estudio de la alergia a frutos secos (FS). Objetivo: Evaluar la capacidad diagnóstica de una micromatriz comercial de proteínas alergénicas en la alergia a cacahuete, avellana y nuez. Métodos: Se determinó la sIgE en pacientes alérgicos a FS mediante la micromatriz ISAC 112, e ImmunoCAP en los pacientes con sIgE negativa frente a los componentes de ISAC. Además, se realizó ImmunoCAP frente a Ara h 9, Cor a 8 y Jug r 3 en un subgrupo de pacientes sensibilizados a LTP. La sIgE detectada por ImmunoCAP fue comparada con los rangos de ISAC. Resultados: La mayoría de los alérgicos a cacahuete (66,7%), avellana (80,5%) y nuez (84%) estaba sensibilizados a su LTP. Sin embargo, no se detectó sIgE frente a los componentes de ISAC en el 33,3% de alérgicos a cacahuete, 13,9% de alérgicos a avellana y 13,6% de los alérgicos a nuez. El ImmunoCAP permitió detectar sIgE a Ara h 9 en 61,5%, Cor a 8 en 60% y Jug r 3 en 83,3% de los ISAC negativo. En el subgrupo LTP, ImmunoCAP (94,4%) fue superior a ISAC (72,2%) en la detección de sIgE a Ara h 9 (p<0,05). La sIgE frente a Cor a 8 y Jug r 3 fue detectada de forma similar por ambas técnicas. Conclusiones: La micromatriz ISAC es adecuada para el diagnóstico de alergia a avellana y nuez. La sensibilidad del componente Ara h 9 de ISAC debe ser mejorada (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Hipersensibilidade a Noz/imunologia , Arachis/imunologia , Hipersensibilidade a Amendoim/imunologia , Corylus/imunologia , Hipersensibilidade/diagnóstico , Hipersensibilidade/imunologia , Testes Imunológicos/instrumentação , Testes Imunológicos/métodos , Testes Imunológicos , Técnicas Imunológicas/métodos , Testes Imunológicos/classificação , Testes Imunológicos/estatística & dados numéricos , Testes Imunológicos/normas , Técnicas Imunológicas/instrumentação , Técnicas Imunológicas/normas , Técnicas Imunológicas
19.
Allergol. immunopatol ; 43(3): 272-278, mayo-jun. 2015. tab
Artigo em Espanhol | IBECS | ID: ibc-136334

RESUMO

BACKGROUND: PIDs are a heterogeneous group of genetic illnesses, and delay in their diagnosis is thought to be caused by a lack of awareness among physicians concerning PIDs. The latter is what we aimed to evaluate in Brazil. METHODS: Physicians working at general hospitals all over the country were asked to complete a 14-item questionnaire. One of the questions described 25 clinical situations that could be associated with PIDs and a score was created based on percentages of appropriate answers. RESULTS: A total of 4026 physicians participated in the study: 1628 paediatricians (40.4%), 1436 clinicians (35.7%), and 962 surgeons (23.9%). About 67% of the physicians had learned about PIDs in medical school or residency training, 84.6% evaluated patients who frequently took antibiotics, but only 40.3% of them participated in the immunological evaluation of these patients. Seventy-seven percent of the participating physicians were not familiar with the warning signs for PIDs. The mean score of correct answers for the 25 clinical situations was 48.08% (±16.06). Only 18.3% of the paediatricians, 7.4% of the clinicians, and 5.8% of the surgeons answered at least 2/3 of these situations appropriately. CONCLUSIONS: There is a lack of medical awareness concerning PIDs, even among paediatricians, who have been targeted with PID educational programmes in recent years in Brazil. An increase in awareness with regard to these disorders within the medical community is an important step towards improving recognition and treatment of PIDs


No disponible


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Dessensibilização Imunológica/métodos , Dessensibilização Imunológica/estatística & dados numéricos , Dessensibilização Imunológica , Síndromes de Imunodeficiência/epidemiologia , Síndromes de Imunodeficiência/imunologia , Síndromes de Imunodeficiência/prevenção & controle , Conhecimentos, Atitudes e Prática em Saúde , Inquéritos e Questionários , Alergia e Imunologia/educação , Alergia e Imunologia , Alergia e Imunologia/estatística & dados numéricos , Técnicas Imunológicas/métodos , Técnicas Imunológicas/normas , Técnicas Imunológicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...